remindeer

Chimney and boiler checks in Czechia: how often the law requires them

In Czechia, a chimney serving a solid-fuel boiler must be checked by a chimney sweep once a year and cleaned 2–3 times a year. The boiler itself needs a check at least every 3 years.

Checked 30 October 2026

Chimney cleaning and checks

Decree No. 34/2016 Coll. sets how often a chimney must be cleaned and checked. For appliances up to 50 kW:

  • Solid fuel (wood, coal, pellets), year-round use: cleaning 3× a year, check once a year.
  • Solid fuel, seasonal use (at most 6 months a year): cleaning 2× a year, check once a year.
  • Gas: cleaning and check once a year.
  • Leave at least 3 months between cleanings.

Who does it, and when you need an inspection

The check is always done by a chimney sweep, who gives you a written report. You may clean the chimney of a solid-fuel appliance up to 50 kW yourself, but you can't do the check. The appliance maker or the building documents may set a shorter interval; holiday cottages and some condensing boilers have longer ones.

A chimney inspection (revize) is a more detailed assessment and is not periodic. You need it mainly for a new or altered chimney, when changing fuel, before replacing a boiler or stove with a different type or output, and after a chimney fire.

Solid-fuel boiler: every 3 years

A solid-fuel boiler rated 10 to 300 kW that feeds central heating must be checked at least once every three years by a qualified person trained by the manufacturer, listed in the official register. The duty lies with whoever operates the boiler; you show the certificate to the authority only on request, and skipping the check can cost a fine of up to CZK 20,000.

For a gas boiler in a family house or your own flat, we found no single statutory interval for regular servicing. Check the manual and the warranty terms for how often the maker wants it serviced. The chimney of a gas boiler still needs a sweep's check once a year.

Heating-season calendar

  • September to October: chimney check and first cleaning.
  • January: second cleaning for solid fuel.
  • April to May: third cleaning for year-round use.
  • Every 3 years: solid-fuel boiler check.

In Remindeer, pick Chimney inspection and enter the next check date; it repeats every year. For the boiler add Boiler / gas service, and for solid fuel set it to repeat every 3 years.

Set up a reminder for free